Lighthouse has a new layout. Prefer the old one? Return to the old layout, and switch back any time from the link at the top of each page.

Activity (RSS)

Monday, March 02 2009
15 Dependency imports are not validated. was updated
  • onyxfish
    • Milestone set to 0.4
    by onyxfish at 12:41 PM
0.5 was updated by onyxfish at 12:41 PM 2 more events
 
4 of 13 tickets remain in this milestone
0.4 was updated by onyxfish at 12:41 PM 2 more events
 
0 of 4 tickets remain in this milestone
24 Scanning in Lineart Mode causes a buffer overflow in PIL. was updated
  • onyxfish
    • Milestone set to 0.5
    by onyxfish at 12:40 PM
27 Create a script to dump scanner information as an aid to debugging. was updated
  • onyxfish
    • Milestone set to 0.4
    by onyxfish at 12:40 PM
29 Handle devices that specify their valid resolutions as a SANE_Range. was updated
  • onyxfish
    • Milestone set to 0.4
    by onyxfish at 12:39 PM
  • onyxfish
    • State changed from new to open
    by onyxfish at 10:35 AM
  • onyxfish
    onyxfish created the ticket at 10:35 AM

    Some devices specify a range of valid resolutions, rather than a list.

30 Fold python-gtkmvc and SaneMe dependencies into the distribution. was updated
  • onyxfish
    • Milestone set to 0.4
    by onyxfish at 12:39 PM
  • onyxfish
    • State changed from new to open
    by onyxfish at 12:36 PM
  • onyxfish
    onyxfish created the ticket at 12:36 PM

    These two dependencies are uncommon enough in repositories that it really is not fair to expect users to dig them up and install them. For the sake of easy inst...

Saturday, February 28 2009
28 Add support for inserting OCR data into output. was updated
Friday, February 27 2009
27 Create a script to dump scanner information as an aid to debugging. was updated
  • onyxfish
    • State changed from new to open
    by onyxfish at 9:56 PM
  • onyxfish
    onyxfish created the ticket at 9:56 PM

    There should be a script that end users can run which dumps all the information about there scanner to a text log, so that it can be attached to tickets.

26 Support Djvu output. was updated
Monday, February 23 2009
Expanded device handling preferences.... was committed by Christopher Groskopf at 11:14 PM
25 nostaples hangs with exception detecting scanner was updated
  • onyxfish
    • State changed from open to hold
    by onyxfish at 9:54 PM

    This error should be resolved by this SaneMe commit, which will part of the release that rolls out along with the next version of NoStaples. I will hold this t...

Merge branch 'master' of git@github.c... was committed by Christopher Groskopf at 10:04 AM
Moved thumbnail scaling mode definiti... was committed by Christopher Groskopf at 10:04 AM
Iterative work on intelligent device ... was committed by Christopher Groskopf at 12:13 AM
Sunday, February 22 2009
25 nostaples hangs with exception detecting scanner was updated
  • Ron Young
    Ron Young commented at 11:53 PM

    I have sane-utils installed (version 1.0.14-5 -- ubuntu 8.04).

    Here is the output from scanimage:

    Script started on Sun 22 Feb 2009 09:26:55 PM PST ron@ron-amd6...

  • onyxfish
    • Tag set to exception, networked-scanner, sane
    • State changed from new to open
    by onyxfish at 10:18 PM

    Thanks for the ticket Ron. This is the second time I've seen this traceback in a log. It appears that some SANE devices either don't have names at all, or their...

  • Ron Young
    Ron Young created the ticket at 5:04 PM

    I am trying to run the distributed nostaples & saneme under ubuntu 8.10 amd64 with a network connected brother mfc440cn scanner/printer. nostaples throws an unh...

Added comments elaborating on voodoo ... was committed by Christopher Groskopf at 5:01 PM
22 Sane Options need to be set at the time the user selects them. was updated
  • onyxfish
    • State changed from open to resolved
    by onyxfish at 4:51 PM

    (from [542ff19541ab2b0d81d8055d4f6e1384162324c5]) Major code-flow revision so that scanner options could be set in advance of scanning.

    Mode and resolution are ...

Major code-flow revision so that scan... was committed by Christopher Groskopf at 4:51 PM
24 Scanning in Lineart Mode causes a buffer overflow in PIL. was updated
  • onyxfish
    • State changed from new to open
    by onyxfish at 3:34 PM
  • onyxfish
    onyxfish created the ticket at 3:34 PM
Fixing previous bad commit. http://gi... was committed by Christopher Groskopf at 3:08 PM
23 Invalid scanning devices such as webcams should be automatically blacklisted. was updated
  • onyxfish
    • State changed from open to resolved
    by onyxfish at 1:12 PM

    (from [9c5bd3433d424bf6cf72a4bc25869e5f668c18f7]) Added automatic recognition of unsupported devices (i.e. webcams).

    [#23 state:resolved] http://github.com/bou...

  • onyxfish
    onyxfish commented at 11:03 AM

    Actually it would be better to keep a separate "Unsupported devices" list. Each time the available scanners are updated all devices are validated to ensure that...

Added automatic recognition of unsupp... was committed by Christopher Groskopf at 1:12 PM
Removing debug code that was accident... was committed by Christopher Groskopf at 12:49 AM
10 It should be possible to blacklist a device that is not supported. was updated
  • onyxfish
    • State changed from open to resolved
    by onyxfish at 12:46 AM

    (from [6cd67b802d07021c0d88ed53a1d8504c095f4d38]) Implemented multiple new preferences.

    Keywords saved for autocompletion can now be removed. [#17 state:resolve...

17 Previously used keywords can not be removed. was updated
  • onyxfish
    • State changed from open to resolved
    by onyxfish at 12:46 AM

    (from [6cd67b802d07021c0d88ed53a1d8504c095f4d38]) Implemented multiple new preferences.

    Keywords saved for autocompletion can now be removed. [#17 state:resolve...

Implemented multiple new preferences.... was committed by Christopher Groskopf at 12:46 AM
Saturday, February 21 2009
23 Invalid scanning devices such as webcams should be automatically blacklisted. was updated
  • onyxfish
    • State changed from new to open
    by onyxfish at 9:10 PM
  • onyxfish
    onyxfish created the ticket at 9:10 PM

    Is there a way of filtering these devices other than by parsing their names? At the very least devices that do not have the necessary options for NoStaples to f...

Friday, February 20 2009
6 The PDF Properties expander's state is not stored between sessions. was updated
  • onyxfish
    • State changed from open to resolved
    • Tag changed from gconf, gui, preferences, save to gconf, gui, pdf, preferences, save
    by onyxfish at 11:05 PM

    (from [99c25be4b18a3098971e6ca4880db71c5795ef52]) Extracted generic versions of property setters and state callbacks into utility classes.

    Revised "PDF Properti...

21 The PDF Properties expander should be retitled Document Metadata. was updated
  • onyxfish
    • State changed from open to resolved
    by onyxfish at 11:05 PM

    (from [99c25be4b18a3098971e6ca4880db71c5795ef52]) Extracted generic versions of property setters and state callbacks into utility classes.

    Revised "PDF Properti...

Extracted generic versions of propert... was committed by Christopher Groskopf at 11:05 PM
4 Launching the About dialog causes a exception. was updated
Fixed crash when launching About dial... was committed by Christopher Groskopf at 10:27 PM
Fixed thread exception handling so th... was committed by Christopher Groskopf at 10:27 PM