onyxfish March 8th, 2009 @ 04:07 PM
- State changed from new to open
-
onyxfish March 17th, 2009 @ 11:26 PM
As it turns out, the SANE API specification explicitly states that resolution can only be specified in DPI. What is causing the problems that have been reported is that devices are allowed to specify this using a SANE_TYPE_FIXED value, which NoStaples has not supported.
-
onyxfish March 17th, 2009 @ 11:27 PM
- State changed from open to hold
(from [d8b751e6a9d7279a1e81206f0437edb3c54c99d7]) Experimental fix for Fixed Point resolution values/constraints.
This needs to be tested. [#37 state:hold] http://github.com/bouvard/nostap...
-
onyxfish March 18th, 2009 @ 10:15 AM
- State changed from hold to fix-needs-tested
-
onyxfish March 18th, 2009 @ 10:32 AM
- Title changed from Handle resolutions specified in non-dpi units. to Handle resolutions specified as fixed-point variables.